485848002__Y (waveform)

ERBESSD / 485848002 · sensor attached · replace sensor · analysis runs

Priority

high (score 13.00, higher is worse), calculated 2026-09-07 23:43:30+0000 by analysis 0b60da320135c2a6e8dba6c815660864.

LevelScoreCalculatedAnalysis
high 13.00 2026-09-07 23:43:30+0000 0b60da320135c2a6e8dba6c815660864
high 13.00 2026-09-07 23:42:23+0000 2131deae57713765bab4963b3b8f03a9

Latest KPI values (GET /mpoints-streams/{id}/kpi)

30 measurements; latest 2026-09-04 05:40.

KPILatest valuePoints in trend
rms0.773396312491572130
velocity_rms_10_1000hz22.7440315667377830
velocity_rms_2_1000hz22.7444858343901630
velocity_rms_2_max22.74449931239784630
velocity_rms_10_max22.74404504501466630
peak1.454240471548892430
peak2peak2.190735088818773830
crest_factor1.880330236982788130
kurtosis1.759351335550655830
envelope_rms0.0093234400144368730
envelope_peak_score0.030

Diagnostic findings (GET /sva/0b60da320135c2a6e8dba6c815660864/symptoms and /changes/active)

SymptomActiveDetectionsPossible faults
symptomWaveformSkewness yes 30 active of 30 sensorIssue (70%), structuralLooseness (30%)

Trend scalars at this measuring point (GET /scalars/?sensor_id=…)

Scalars are keyed by sensor, not by stream — the link to this measuring point is derived: this point's streams name their active sources, the sources name their sensors, and the sensors' scalars are what you see here. The scalars page draws the whole chain.

The sensors at this measuring point report no trend scalars.

rpm: outside 600–3600 RPM an rpm scalar is required — without it, bearing analysis silently returns nothing.

Embedded analysis view

This iframe is the one thing the browser loads straight from the deployment. Its URL carries only the stream id — no credential — and this page's own Content-Security-Policy: frame-src header is what allows the frame (the deployment sets no framing restriction of its own).