485848006__X (waveform)

ERBESSD / 485848006 · sensor attached · replace sensor · analysis runs

Priority

high (score 13.00, higher is worse), calculated 2026-09-07 23:43:25+0000 by analysis 44ff78069b353be828f62a1964f1df07.

LevelScoreCalculatedAnalysis
high 13.00 2026-09-07 23:43:25+0000 44ff78069b353be828f62a1964f1df07
high 13.00 2026-09-07 23:42:25+0000 e1756ec7bed7ddab152293be705425be

Latest KPI values (GET /mpoints-streams/{id}/kpi)

30 measurements; latest 2026-09-04 05:40.

KPILatest valuePoints in trend
rms2.147414898983604430
velocity_rms_10_1000hz17.3515193230854530
velocity_rms_2_1000hz17.76946279347894430
velocity_rms_2_max17.7694671597681530
velocity_rms_10_max17.3515237945447930
peak4.47836518620840130
peak2peak8.41251400447103130
crest_factor2.08546806130853530
kurtosis2.675228294593746430
envelope_rms0.444166519120041230
envelope_peak_score0.4382582434099279730

Diagnostic findings (GET /sva/44ff78069b353be828f62a1964f1df07/symptoms and /changes/active)

SymptomActiveDetectionsPossible faults
symptomDominant2xLineFrequency yes 15 active of 15 vfdElectricalNoise (60%), softFoot (30%), looseConnections (10%)

Trend scalars at this measuring point (GET /scalars/?sensor_id=…)

Scalars are keyed by sensor, not by stream — the link to this measuring point is derived: this point's streams name their active sources, the sources name their sensors, and the sensors' scalars are what you see here. The scalars page draws the whole chain.

The sensors at this measuring point report no trend scalars.

rpm: outside 600–3600 RPM an rpm scalar is required — without it, bearing analysis silently returns nothing.

Embedded analysis view

This iframe is the one thing the browser loads straight from the deployment. Its URL carries only the stream id — no credential — and this page's own Content-Security-Policy: frame-src header is what allows the frame (the deployment sets no framing restriction of its own).